1. Spray pressure is insufficient, poor atomization: Ruoyin water ball valve was dirt put aside, you can remove the inlet valve, with cloth to remove dirt; Ruoyin cup damaged, can replace the new leather bowl; if the connection site Seal is not installed, or because the seal is damaged and leakage, can be installed or replace the seal.

2. Spray does not form a fog: Ruoyin nozzle body of the inclined hole is blocked by dirt, can clear the inclined hole; if the nozzle hole can be opened to clean the nozzle plugging, but can not use wire or copper needle and other hard objects poke holes to prevent Hole to expand, so that the quality of the spray worse; if the casing filter plugging or over water valve ball set aside, you should clean the filter and wash the ball put the dirt.

3. Switch leakage or unsteadiness: If the switch cap is not tightened, the switch cap should be tightened; if the gasket on the switch core is worn, the gasket should be replaced; the switch can not be replaced because the switch is too long or too long , The switch core due to the erosion of the chemical bonding and should be removed parts cleaning in kerosene or diesel; remove difficulties, you can soak in kerosene for a period of time, and then remove the demolition can not be hard beat .

4. Leakage of joints: If the joint is loose, the nut should be tightened; if the washer is not flat or damaged, the washer should be flattened or the washer replaced; if the washer is shrunk and hardened, it can be soaked in animal oil reuse.